Product description
- pH range: 2 … 11
- Pressure range: 0 – 1 bar, no pressure surges and/or fluctuations
- Temperature range: 1 – 45 °C
- Integrated automatic temperature compensation
Scope of supply
- WP7: sensor, membrane cap, electrolyte
Areas of application
- Fresh water, surfactants are tolerated

Product description
- pH range: 2 … 11
- Pressure range: 0 – 1 bar, no pressure surges and/or fluctuations
- Temperature range: 1 – 45 °C
- Integrated automatic temperature compensation
Scope of supply
- WP10: sensor, membrane cap, electrolyte
Areas of application
- All types of water treatment, surfactants are generally tolerated

Product description
- pH range: 2 … 11
- Pressure range:
Operation without retaining ring: 0 … 0.5 bar, no pressure surges and/or vibrations
Operation with retaining ring: 1.0 bar, no pressure surges and/or vibrations - Temperature range: 1 – 45 °C
- Integrated automatic temperature compensation
- Run-in time during first commissioning: approx. 60 min.
- Response time: T90 aprox. 12 min.
- Zero adjustment: not required
- Absence of disinfectant: max. 24 h
Scope of supply
- WP10.1: sensor, membrane cap, electrolyte
Areas of application
- All types of water treatment (e.g., CIP systems, rinsers), including seawater, especially for high H2O2 concentrations.